手机版 |
产品分类 |
半导体行业专用仪器
OAI Model 212紫外光刻机
OAI Model 800E紫外光刻机
OAI掩膜光刻机Model 6000
Model 6020S紫外光刻机
URE-2000/35A型紫外单面光刻机
URE-2000B型紫外单面光刻机
ZEP520A电子束光刻胶
AZ 1500系列i线光刻胶
德国ALLRESIST导电胶AR-PC5090和AR-PC5091
英国EM SML Resist电子束光刻胶
光学仪器及设备
海德堡μMLA桌面无掩模光刻机
OAI UV Led光源
URE-2000/35AL型紫外单面光刻机
URE-2000/30型紫外单面光刻机
URE-2000S/35L(B)型双面光刻机
URE-2000S/35L(A)型紫外双面光刻机
URE-2000S/25S型双面光刻机
URE-2000S/A8型紫外双面光刻机
URE-2000S/A型紫外双面光刻机
URE-2000S/B型紫外双面光刻机
其他
美国NanoArch陶瓷树脂精密3D打印机MicroArch S240
日立Hitachi离子溅射仪MC1000
英国Nanomagnetics振动样品磁强计VSM
英国HHV溅射镀膜仪BT150,BT300
法国Plassys微波等离子体化学气相沉积系统SSDR 150
法国Alyxan高分辨质子传递反应质谱PTR-FTICR MS
德国Sentech光伏测量仪MDPspot
德国Sentech光伏测量仪MDPmap
德国Sentech光伏测量仪器MDPpro
MDPinlinescan在线寿命和电阻率逐行扫描仪
制样/消解设备
NIE-4000离子束刻蚀系统
牛津Oxford等离子体刻蚀机PlasmaPro 80 RIE
美TED Pella高分辨离子溅射仪208HR
美TED PELLA自动离子溅射仪108AUTO
PDC-002美国Harrick扩展型等离子清洗机
PDC-32G-2美国Harrick基本型等离子清洗机
德国Diener等离子清洗机Nano
德国Diener等离子清洗机Zepto
德国Diemer等离子清洗机Femto
德国Diener等离子清洗机
分子生物学仪器
IZON qEV尺寸排阻柱
德国Kruss液滴形状分析DSA25
等离体共振分析仪MP-SPR Navi 220A
Micro Pulser电穿孔仪
英国Cleaver高分辨率垂直电泳系统CSQ20
瑞士罗氏Roche全自动核酸纯化仪MagNA
英国CLEAVER水平电泳系统Horizontal Gel
台式钙流检测工作站FlexStation 3
美国Molecular光吸收型酶标仪SpectraMax 190
美国Sciex遗传分析系统GenomeLab GeXP
清洗/消毒设备
美国必能信Branson台式超声波清洗机CPX1800-8800系列
美国Uvitron全功能紫外面光源Intelli-RAY 400W
紫外线杀菌消毒台灯QD-UV-01
英国Glovebox学术手套箱Academic
英国Glovebox真空室手套箱
PDC-MG美国Harrich高集成度等离子清洗机
美国Uvitron紫外面光源INTELLI-RAY 400W
英国AMBA曝光灯AM7977X,AM11353X(AM7000)
SUSS苏斯光刻机用曝光灯HBO 200W/DC ,HBO 350W/S,
P-Laser激光清洗系统
光谱检测分析仪
曰立Hitachi塞曼原子吸收光谱仪ZA3000
德国neaspec纳米傅里叶红外光谱仪nano-FTIR
美Thorlabs傅立叶红外光谱仪OCS201C,OCS202C,OCS203
德国Bruker ALPHA II FTIR傅立叶变换近红外光谱仪
德国Bruker FT-NIR光谱仪Tango,MPA,Matrix-I
BRAVO手持式拉曼光谱仪
日本JEOL X射线荧光光谱仪JSX-1000S
Dimension FastScan德国BRUKER原子力显微镜AFM
比表面积测定仪
英国MML纳米压痕仪NanoTest Vantage
Kla纳米压痕仪G200,G200X,iMicro
接触角测定仪JY-PHa
德国KRUSS标准型接触角测量仪DSA25
100标准型接触角测量仪/Contact angle measuring dev
100S接触角测量仪
德国Mecwins扫描式激光分析仪SCALA
色谱仪
法SEBIA全自动毛细管电泳仪Capillarys 3 OCTA
LTQ Orbitrap XL ETD液质联用系统
赛默飞Themo Scientific液相色谱系统Vanquish UHPLC
集成型毛细管离子色谱ICS-40
模块化气相色谱仪TRACE 1300
赛默飞多功能离子色谱ICS-5000
X射线仪器
日本Rigaku智能多功能X射线衍射仪Smartlab SE
日本理学XRD X射线多晶衍射仪SmartLab
日本理学台式XRD X射线衍射仪Miniflex 600
德国YXLON高分辨率X射线检测设备-平板探测器
临床检验仪器设备
美国PerkinElmer多功能液闪/发光分析仪MicroBeta
Molecular读板机SpectraMax iD5
无损检测/无损探伤仪器
美国SONIX超声波扫描显微镜ECHO-VS, ECHO Pro
英国AML邦定机AWB 04 & 08 Platform
生物工程设备
DSA100德Kruss液滴形状分析仪
瑞士Cytosurge注入器iyFluidFM BOT
微生物检测仪器
新西兰IZON外泌体分离鉴定系统qNano
Thermo Scientific微生物培养箱Precision
波谱仪器
英国Oxford实验室用智能核磁共振波谱仪Pulsar
细胞生物学仪器
美国Bd单细胞分析系统Rhapsody TM
气体检测仪
日本A&D粒子计数器(粒度计)SV-1A
成像系统
ImageXpress Pico自动细胞成像
质谱检测分析仪
TSQ Fort三重四极杆质谱仪
磁学测量仪器
美Quantum Design多铁材料磁电测量系统Super-ME-II
激光粒度仪
美SD粒子碰撞噪声检测仪4511A、4511L、4511M4、4511M6
联系方式 |
产品系列
产品描述
产品详情
Protective Coating PMMA Electra 92 (AR-PC 5090)
Conductive protective coating for non-novolak-based e-beam resists
Top layer for the dissipation of e-beam charges on insulating substrates
英国ALLRESIST防护涂层PMMA Electra 92 (AR-PC 5090)
用于非氮基电子束电阻的导电保护涂层
用于在绝缘衬底上耗散电子束电荷的顶层
Characterisation 描述
- as protective coating, this resist is not sensitive to light / radiation
- thin, conductive layers for the dissipation of charges during electron exposure
- coating of non-novolac PMMA, CSAR 62, HSQ et al.
- longterm-stable and cost-efficient alternative to Espacer
- easy removal with water after exposure
- polyaniline-derivative dissolved in water and IPA
Conductivity 导电率
Resistance measurements of AR-PC 5090.02 layers obtained after spin deposition. For thinner films, the resistance increases and the conductivity decreases.
Process parameters 工艺参数
REM dissipation of charges
200 nm-squares written on quartz without distortion caused by charges with AR-P 662.04 and AR-PC 5090.02
Protective Coating PMMA Electra 92 (AR-PC 5090)
Process conditions
This diagram shows exemplary process steps for resist Electra 92 - AR-PC 5090.02 and PMMA-resist AR-P 664.04.
All specifications are guideline values which have to be adapted to own specific conditions.
Processing instructions
The conductivity may be varied by adjusting the thickness with different rotational speeds. Thicker layers of 90 nm thus have a 2.5 times higher conductivity as compared to 60 nm thick layers.
For the build-up of an even conductive layer, the substrate should be wetted with the resist solution before the spin process is started.
Protective Coating Novolac Electra 92 (AR-PC 5091)
Conductive protective coating for novolac-based e-beam resists
Top layer for the dissipation of e-beam charges on insulating substrates
Characterisation
- as protective coating, this resist is not sensitive to light / radiation
- thin, conductive layers for the dissipation of charges during electron exposure
- coating of novolac-based e-beam resist AR-N 7000
- longterm-stable and cost-efficient alternative to Espacer
- easy removal with water after exposure
- polyaniline-derivative dissolved in water and IPA
Conductivity
Resistance measurements of AR-PC 5091.02 layers obtained after spin deposition. For thinner films, the resistance increases and the conductivity decreases.
Note: Novolac-based e-beam resists possess other surface properties than CSAR 62 or PMMA. AR-PC5091 was thus developed with a different solvent mixture. In all other respects however, the polymer composition of AR-PC 5090 and AR-PC 5091 is identical so that both resists are referred to as “Electra 92“.
Process parameters
REM dissipation of charges
50 nm lines written on glass at a pitch of 150 nm with AR-N 7520.07 and AR-PC 5091.02
Protective Coating Novolac Electra 92 (AR-PC 5091)
Process conditions
This diagram shows exemplary process steps for resist Electra 92 (AR-PC 5091.02) and e-beam resist AR-N 7520.07neu. All specifications are guideline values which have to be adapted to own specific conditions.
Processing instructions
The conductivity may be varied by adjusting the thickness with different rotational speeds. Thicker layers of 90 nm thus have a 2.5 times higher conductivity as compared to 60 nm thick layers. In the case that crack formation is observed after tempering of the protective coating, the tempering step can be omitted.
For the build-up of an even conductive layer, the substrate should be wetted with the resist solution before the
spin process is started.
Protective Coating Electra 92
Application examples for PMMA-Electra 92
Shelf live of Electra 92
Conductivity properties of differently aged Electra 92 batches
The conductivity was determined as a function of the measured temperature. At temperatures < 100 °C, both resists show a virtually identical conductivity. Electra 92 is thus characterised by a very long shelf life. Conductivity measurements up to a temperature of 160°C which were performed directly on a hotplate showed a large increase of the conductivity by a factor of 10 (see diagram). This fact is due to the complete removal of water from the layer. After a few hours of air humidity absorption under room conditions, the conductivity decreases again to
the initial value. In the high vacuum of e-beam devices, the water is also completely removed and the conductivity thus increases accordingly. This effect has been demonstrated in direct conductivity measurements under mediate vacuum conditions. Temperatures above 165 °C destroy the polyaniline irreversibly and no conductivity is observed any more
CSAR 62 on glass with Electra 92 for deriving
30 – 150 nm squares of CSAR 62 on glass
The combination of CSAR 62 with Electra 92 - AR-PC5090.02 offers the best options to realise complex ebeam structuring processes on glass or semi-insulating substrates like e.g. gallium arsenide. The excellent sensitivity and highest resolution of the CSAR are complemented harmoniously by the conductivity of Electra 92.
CSAR 62 and Electra 92 on glass
At a CSAR 62 film thickness of 200 nm, squares with an edge length of 30 nm could reliably be resolved on glass.
PMMA Lift-off on glass with Electra 92
200 nm squares produced with 2-layer PMMA lift-off
Initially, the PMMA resist AR-P 669.04 (200 nm thickness) was coated on a quartz substrate and tempered. The se cond PMMA resist AR-P 679.03 was then applied (150nm thickness) and tempered, followed by coating with Electra 92. After exposure, Electra 92 was removed with
water, the PMMA structures were developed (AR 600-56) and the substrate vaporised with titanium/gold. After a liftoff with acetone, the desired squares remained on the glass with high precision.
PMMA-Lift-off auf Glas mit Electra 92
Protective Coating Electra 92
Application examples for PMMA Electra 92
Electra 92 with HSQ on quartz
20 nm bars of HSQ, prepared on quartz AR-PC 5090.02
After a coating of Electra 92 on an HSQ resist, even this resist can be patterned on a quartz substrate with very high quality. The HSQ resist (20 nm thickness) was irradiated with the required area dose of 4300 μC/cm2.
SX AR-PC 5000/90.2 was subsequently completely removed within 2 minutes with warm water and no residues could be detected. After development of the HSQ resist, the structures with high-precision 20 nm bars remained.
Lift-off struktures on garnet
Lift-off structures on garnet (University of California, Riverside,Department of Physics and Astronomy)
Plasmonic structures on quartz
Silver nanoparticles on quartz, generated with AR-P 672.11 and ARPC 5090.02 (Aarhus University, Denmark)
Application examples for Novolac Electra 92
Electra 92 and AR-N 7700 on glass
60 – 150 nm squares (100 nm height) on glass with AR-N 7700.08 and AR-P 5091.02
Novolac-based e-beam resists possess other surface properties than CSAR 62 or PMMA. For this reason, AR-PC5091.02 was designed with a different solvent composition. E-beam resist AR-N 7700.08 was at first spincoated on glass, dried, coated with Electra 92 and baked at 50 °C. After irradiation, the Electra layer was removed within 1 minute with water and the e-beam resist then developed. The resulting resolution of 60 nm is very high for chemically amplified resists.